Absolute Quantification of Total Hemoglobin in Whole Blood by High-Performance Liquid Chromatography Isotope Dilution

Mengyun Pan1, Yanli Lu1,2, Liuxing Feng1

  • 1Division of Chemical Metrology and Analytical Science, National Institute of Metrology, Beijing 100029, China.

Analytical Chemistry
|August 17, 2022
PubMed

Accurate and traceable measurement of hemoglobin (HGB) is of great importance in clinical testing. Although the HiCN method is the internationally accepted conventional reference method for this biomarker and frequently used in clinical routine diagnostics, the HiCN method cannot be traceable to the International System of Units (SI) and thus does not meet highest metrological demands. In this study, an absolute quantitative approach for total HGB in a whole blood sample is proposed based on the determination of natural Fe and S present in the heme-group of HGB by HPLC isotope dilution ICP-MS. IRMM/IFCC-467 is used for method validation, and then clinical blood samples are measured by the established strategy and HiCN method. The measurable ranges of total HGB were 10.0-240.0 g L-1. Limits of detection via Fe and S were 0.01 and 0.07 g L-1, respectively. The intra-assay imprecision CVs via Fe and S were 0.89-1.35 and 0.99-1.56%, and the interassay CVs were 1.19-2.15 and 1.55-2.55%, respectively. Good agreement was achieved in the method validation. In the comparison with HiCN experiments, the ID-ICP-MS assays via Fe and S showed correlations of r2 = 0.991 and 0.970 against HiCN methods. Moreover, the concentration of transferrin (Tf) was also simultaneously measured. This strategy has potential to serve as a reference measurement procedure for total HGB in whole blood, which could be traceable to SI and does not require toxic derivation reagent.

Related Concept Videos

High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.5K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
908
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
878