Light flash and odor during proton beam therapy for pediatric patients: a prospective observational study
Masashi Mizumoto1, Yoshiko Oshiro1, Toshio Miyamoto1
1Department of Radiation Oncology, University of Tsukuba, Tsukuba, Japan.
Abstract:
Light flash and odor during radiation therapy are well-known phenomena, but the details are poorly understood, particularly in pediatric patients. Therefore, we conducted a prospective observational study of these events in pediatric patients (age ≤20 years old) who received radiotherapy at our center from January 2019 to November 2021. Light flash and odor were evaluated using a patient-reported checklist including the presence, strength, and duration of the phenomenon, and color of light or type of odor. 53 patients who received proton therapy (n=47) and photon radiotherapy (n=6) were enrolled in this study. The median age of the patients was 10, ranged from 5 to 20. The patients who was able to see the light flash was 4, and all of them received retina irradiation. This was equivalent to 57% of the patients who received radiotherapy to retina (n=7). The light was bright and colored mainly blue and purple, which seemed to be consistent with Cherenkov light. Odor was sensed by 9 (17%) patients, and seven patients of the 9 received nasal cavity irradiation. This was equivalent to 41% of the patients who received nasal cavity irradiation (n=17). Other 2 patients received proton therapy to brain tumor. The odors were mainly described as plastic, burnt and disinfectant, which may be caused by ozone generated during irradiation. These data suggest that pediatric patients with retinal and nasal cavity irradiation frequently sense light flashes or odor. So adequate care is necessary so that these patients are not worried about this phenomenon.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...