Related Experiment Video
Updated: Aug 31, 2025

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Early predictors of oxygenator exchange during veno-venous extracorporeal membrane oxygenation: A retrospective
Nao Umei1,2, Shingo Ichiba1,2, Yuki Genda1,2
1Department of Anesthesiology, Nippon Medical School, Tokyo, Japan.
Introduction:
Oxygenator exchange during extracorporeal membrane oxygenation (ECMO) is a life-threatening procedure. D-dimer has been used to predict oxygenator failure, but it is a parameter used a few days before oxygenator exchange. This study investigated parameters before and immediately after ECMO initiation that predict oxygenator exchange.
Methods:
This was a single-center, retrospective study of 28 patients who received veno-venous ECMO with heparin/silicone-coated polypropylene oxygenator (NSH-R HPO-23WH-C; Senko Medical Inc., Tokyo, Japan), due to acute respiratory failure, from April 2015 to March 2020. Clinical data before ECMO initiation and during the first 3 days on ECMO were compared between the patients with oxygenator exchange (exchange group) and those without oxygenator exchange (non-exchange group).
Results:
Nine (32%) patients required oxygenator exchange. The exchange group had significantly higher white blood cell count (WBC) (16,944 ± 2423/µL vs 10,342 ± 1442/µL, p < 0.05) and Acute Physiology and Chronic Health Evaluation (APACHE) II score (31 ± 5 vs 25 ± 8, p < 0.05) before ECMO initiation than the non-exchange group. The partial pressure of oxygen at the outlet of the oxygenator (PO2 outlet) and activated partial thromboplastin time (aPTT) during the first 3 days on ECMO were significantly lower in the exchange group than in the non-exchange group.
Conclusions:
High WBC and APACHE II score before ECMO initiation, low PO2 outlet, and aPTT during the first 3 days on ECMO were associated with oxygenator exchange during veno-venous ECMO. These parameters could be used to avoid unexpected oxygenator exchange.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Transport in the Blood