Related Experiment Video
Updated: Aug 31, 2025

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Noncontact assessment for fatigue based on heart rate variability using IR-UWB radar
Sarfaraz Ahmed1, Yonggu Lee2, Young-Hyo Lim2
1Department of Electronics and Computer Engineering, College of Engineering, Hanyang University, 04763, Seoul, Republic of Korea.
Abstract:
Physical fatigue can be assessed using heart rate variability (HRV). We measured HRV at rest and in a fatigued state using impulse-radio ultra wideband (IR-UWB) radar in a noncontact fashion and compared the measurements with those obtained using electrocardiography (ECG) to assess the reliability and validity of the radar measurements. HRV was measured in 15 subjects using radar and ECG simultaneously before (rest for 10 min before exercise) and after a 20-min exercise session (fatigue level 1 for 0-9 min; fatigue level 2 for 10-19 min; recovery for ≥ 20 min after exercise). HRV was analysed in the frequency domain, including the low-frequency component (LF), high-frequency component (HF) and LF/HF ratio. The LF/HF ratio measured using radar highly agreed with that measured using ECG during rest (ICC = 0.807), fatigue-1 (ICC = 0.712), fatigue-2 (ICC = 0.741) and recovery (ICC = 0.764) in analyses using intraclass correlation coefficients (ICCs). The change pattern in the LH/HF ratios during the experiment was similar between radar and ECG. The subject's body fat percentage was linearly associated with the time to recovery from physical fatigue (R2 = 0.96, p < 0.001). Our results demonstrated that fatigue and rest states can be distinguished accurately based on HRV measurements using IR-UWB radar in a noncontact fashion.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse

