Improved Faster R-CNN for the Detection Method of Industrial Control Logic Graph Recognition

Shilin Wu1,2, Yan Wang2, Huayu Yang2

  • 1Hubei Key Laboratory of Digital Textile Equipment, Wuhan Textile University, Wuhan, China.

Related Concept Videos

Signal Flow Graphs01:18

Signal Flow Graphs

Signal-flow graphs offer a streamlined and intuitive approach to representing control systems, providing an alternative to traditional block diagrams. These graphs use branches to symbolize systems and nodes to represent signals, effectively illustrating the relationships and interactions within the system.
In a signal-flow graph, branches denote the system's transfer functions, while nodes represent the signals. The direction of signal flow is indicated by arrows, with the corresponding...
306
Block Diagram Reduction01:22

Block Diagram Reduction

The process of deriving the transfer function of a control system often involves reducing its block diagram to a single block. This simplification can be achieved through a series of strategic operations, including relocating branch points and comparators. These operations preserve the overall function of the system while allowing for easier manipulation and combination of blocks.
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
282
Comparison between RL and RC circuits01:24

Comparison between RL and RC circuits

An RC circuit consists of resistance and capacitance, while in an RL circuit, capacitance is replaced by an inductor. RL and RC circuits are first-order differential circuits that store energy. An RC circuit stores energy in the electric field, while an RL circuit stores energy in the magnetic field. When connected to a battery, an RC circuit charges the capacitor, causing the current to decrease from maximum to zero upon being fully charged. This increases the voltage across the capacitor from...
4.3K
Sequence Networks of Rotating Machines01:24

Sequence Networks of Rotating Machines

A Y-connected synchronous generator, grounded through a neutral impedance, is designed to produce balanced internal phase voltages with only positive-sequence components. The generator's sequence networks include a source voltage that is exclusively in the positive-sequence network. The sequence components of line-to-ground voltages at the generator terminals illustrate this configuration.
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
135