Bismuth-coated screen-printed electrodes for the simple voltammetric determination of formaldehyde
Nataliya Malakhova1, Polina Mozharovskaia1, Alexander Berhane Kifle1
1Department of Analytical Chemistry, Institute of Chemical Technology, Ural Federal University named after the First President of Russia B. N. Yeltsin, Mira St, 28, Ekaterinburg 620002, Russian Federation. n.a.malahova@urfu.ru.
Abstract:
For the first time, bismuth modified electrodes have been used for the voltammetric detection of formaldehyde (FM). The well-known method of forming formaldehyde hydrazone (FAH) in the presence of hydrazine sulphate was used to convert the hydrated form of FM into its electrochemically active derivative. Various experimental conditions for differential pulse voltammetry were studied to achieve the best analytical performance. The FAH reduction current (FM response) reaches its maximum value at a pH of a phosphate buffer solution of 5.2 ± 0.1 in the presence of 0.09-0.12 M hydrazine sulfate on a bismuth film preliminarily precipitated for 8-12 min from acidic Bi(III) acetate solutions at an electrolysis potential of -1.0 V on the surface of a screen-printed carbon electrode (SPCE). A dendritic-like film structure was created on the SPCE surface. Under the optimized conditions a linear calibration curve over the range of 0.01-5 mg L-1 (0.33-167 μM) FM was achieved, with a detection limit of 0.002 mg L-1 (0.06 μM). The determination of FM in waste water, melt water from snow within the city industrial zone, and a widely used pharmaceutical preparation "Endofalk®" with good results revealed the potential applicability of a bismuth modified SPCE (BiSPCE) for trace analysis.
More Related Videos
08:22Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
Related Concept Videos
Potentiometry: Membrane Electrodes
Amperometry: Overview
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Linear-Scan (E vs Time)