Related Experiment Video
Updated: Aug 31, 2025

Preparation of Multifunctional Silk-Based Microcapsules Loaded with DNA Plasmids Encoding RNA Aptamers and Riboswitches
Published on: October 8, 2021
A compact and wideband MIMO antenna for high-data-rate biomedical ingestible capsules
Abdullah J Alazemi1, Amjad Iqbal2
1Department of Electrical Engineering, Faculty of Engineering and Petroleum, Kuwait University, Kuwait City, 13060, Kuwait. aalazem.ku@ku.edu.kw.
Abstract:
Due to recent advancements in complementary metal-oxide-semiconductor (CMOS) cameras, transferring high resolution images and videos are possible in wireless capsule endoscopy. High-data-rates communication is required for such data, which is possible using multiple-input-multiple-output (MIMO) antennas. In this paper, a low-sized, compact, high-data-rate, highly isolated two-element MIMO antenna with a large bandwidth has been proposed at 2.45 GHz for wireless capsule endoscopy. The geometry of the antenna ([Formula: see text]) is kept small using meandered geometry, defected ground structure, and high permittivity of the substrate. A wider bandwidth of 620 MHz (2.15-2.77 GHz) is achieved by exciting dual-modes of the antenna using defected ground structure. Furthermore, a lower mutual coupling between the antennas (30.1 dB at 2.45 GHz) is realized, despite the small edge-to-edge gap of 0.5 mm, using combination of defected ground structure and I-shaped stub. Keeping in mind of system level configuration, this antenna is simulated and measured inside a capsule device by considering effects of the other components and the device itself. The practical measurements are performed by inserting the capsule device (containing the MIMO antenna) inside minced meat. To check the safety and effectiveness of the proposed MIMO antenna, it's specific absorption rate (SAR) and link budget are calculated and validated. In addition, the [Formula: see text] channel specifications are verified which shows satisfactory performance. This antenna has high channel capacity ([Formula: see text] at [Formula: see text]) than single-input-single-output (SISO) antennas, thus, is a suitable choice for high-data-rate capsule endoscopic devices. To the best of the authors' knowledge, this is the first implantable MIMO antenna reported so far with such lower dimension and wider bandwidth.
More Related Videos
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
08:17Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa
Published on: September 27, 2018