Application and Optimization of Luenberger Observer Phase-Locked Loop and Inductance-Free Vector Control Method for

Bo Zeng1, Yuxiang Sun2,3

  • 1College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China.

Related Concept Videos

Phase-lead and Phase-lag Controllers01:22

Phase-lead and Phase-lag Controllers

Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
217
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
245
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
145
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
131
Node Analysis for AC Circuits01:14

Node Analysis for AC Circuits

Consider an angioplasty system featuring a catheter equipped with a turbine, a critical tool for removing plaque deposits from coronary arteries. This intricate medical device operates using a circuit model reminiscent of a dual-node RLC circuit powered by a current-controlled voltage source.
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
368
Inductance: Single-Phase And Three-Phase Line01:28

Inductance: Single-Phase And Three-Phase Line

Understanding the inductance of transmission lines is crucial for efficient design and operation in electrical power systems. This discussion delves into the inductance characteristics of single-phase two-wire and three-phase three-wire transmission lines with equal phase spacing.
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
243