Related Experiment Video
Updated: Aug 31, 2025

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Can Hypotension Episodes that were not Identified in the Non-Invasive Blood Pressure be Detected during Cesarean
Asude Ayhan1, Nükhet Akovalı1, Aynur Camkıran Fırat2
1Department of Anaesthesiology and Reanimation, Faculty of Medicine Başkent University, Ankara, Turkey
Background:
Neuraxial anesthesia is a commonly used technique for cesarean section (C/S) because of its simplicity, rapid onset of action, and the requirement of lower doses of anesthetic agents with the lack of uteroplacental transfer. However, this type of anesthesia often causes sudden onset of hypotension, and its pathogenesis is not yet clearly understood.
Aims:
To evaluate the efficacy and necessity of continuous non-invasive arterial pressure (CNAP) by comparing it with non-invasive blood pressure (NIBP) in order to understand whether it has advantages over oscillometric technique for detection of hypotensive episodes in healthy pregnant women who underwent C/S under neuraxial anesthesia.
Study Design:
A randomized controlled study.
Methods:
This prospective study evaluated healthy pregnant women at term who were scheduled for elective C/S under spinal anesthesia. Subjects were randomly assigned into two groups to receive either CNAP and NIBP, or only NIBP. A 30% decrease in systolic blood pressure from either baseline or the measured values in the first two minutes, or if the systolic blood pressure was less than 90 mmHg, is considered hypotension. Pre-, peri-, and postoperative specifications; newborn characteristics; and complications were recorded and compared.
Results:
A total of 106 individuals were enrolled in the study, with 53 parturients in each group. They were equally distributed in both groups (P > 0.05). The oscillometric method failed to detect hypotension in 8 out of 29 pregnant women who were noted to be hypotensive with CNAP. The number of hypotension events detected was higher, and the time to detection of the first episode of hypotension was shorter in the CNAP group (P > 0.05). A total of four newborns required intensive care unit treatment, one of whom needed mechanical ventilator support, all born to mothers in the CNAP group (P > 0.05).
Conclusion:
Continuous non-invasive arterial pressure in detecting hypotensive episodes does not provide an additional advantage to healthy pregnant women undergoing elective cesarean section.
More Related Videos
08:37Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: