Related Experiment Video
Updated: Aug 31, 2025

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Comparison of Two Types of 1-L Polyethylene Glycol-ascorbic Acid as Colonoscopic Bowel Preparation: A Prospective
Suh Hyun Choi1, Won Eui Yoon1, Seung Hyuk Kim1
1Division of Gastroenterology, Department of Internal Medicine, Seoul Paik Hospital, Inje University College of Medicine, Seoul, Korea.
Background/Aims:
Recently, 1-L polyethylene glycol-ascorbic acid (PEG-Asc) has been used to reduce the volume of preparation agents in colonoscopy. This clinical trial aimed to compare the efficacy and safety of two types of 1-L PEG-Asc (CleanViewAL® [Tae Joon Pharmaceutical Company, Seoul, Korea] and Plenvu® [Norgine, Harefield, United Kingdom]) in average-aged adults.
Methods:
This study was a prospective, randomized, non-inferiority, open-label, phase 4 clinical trial. The primary endpoint was the efficacy evaluated using the Boston bowel preparation scale (BBPS), and the secondary endpoint was clinical safety.
Results:
In total, 173 patients were assigned to either the CleanViewAL® (n=84) or Plenvu® (n=89) group. Overall cleansing successes of 97.6% (82/84) and 98.8% (88/89) were achieved in the CleanViewAL® group and in the Plenvu® group, respectively, showing that CleanViewAL® has similar bowel cleansing efficacy to Plenvu® (95% CI, -0.052 to 0.027; p=0.207). The total BBPS score was 8.67±1.00 and 8.70±0.76 in the CleanViewAL® group and Plenvu® group, respectively (p=0.869). The most common adverse symptom was nausea, and no adverse symptoms requiring hospitalization were reported in either group. There were no cases of critical hypernatremia and liver dysfunction exceeding the common terminology criteria for adverse events grade I. An overall satisfaction score (scale of 1 to 10) showed no difference between the two groups (p=0.289). However, the CleanViewAL® group showed a higher taste satisfaction score (scale of 1 to 5) than the Plenvu® group (CleanViewAL®: 2.90±0.91, Plenvu®: 2.60±0.86, p=0.028).
Conclusions:
Both types of 1-L PEG-Asc, CleanViewAL® and Plenvu®, are effective and safe bowel cleansing agents in average-aged adults. CleanViewAL® was preferred in terms of taste satisfaction.
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Drugs Affecting GI Tract Motility: Adsorbents as Antidiarrheal Agents
Adsorbents...
Drugs Affecting GI Tract Motility: Other Laxatives
Osmotic or saline laxatives, like magnesium hydroxide or milk of...
Drugs for Treatment of Constipation-Predominant IBS

