Related Experiment Video
Updated: Aug 31, 2025

Determination of the Excitation and Coupling Rates Between Light Emitters and Surface Plasmon Polaritons
Published on: July 21, 2018
Optical Anisotropy and Excitons in MoS2 Interfaces for Sensitive Surface Plasmon Resonance Biosensors
Amir Eghbali1, Andrey A Vyshnevyy1, Aleksey V Arsenin1
1Center for Photonics and 2D Materials, Moscow Institute of Physics and Technology (MIPT), 141700 Dolgoprudny, Russia.
Abstract:
The use of ultra-thin spacer layers above metal has become a popular approach to the enhancement of optical sensitivity and immobilization efficiency of label-free SPR sensors. At the same time, the giant optical anisotropy inherent to transition metal dichalcogenides may significantly affect characteristics of the studied sensors. Here, we present a systematic study of the optical sensitivity of an SPR biosensor platform with auxiliary layers of MoS2. By performing the analysis in a broad spectral range, we reveal the effect of exciton-driven dielectric response of MoS2 and its anisotropy on the sensitivity characteristics. The excitons are responsible for the decrease in the optimal thickness of MoS2. Furthermore, despite the anisotropy being at record height, it affects the sensitivity only slightly, although the effect becomes stronger in the near-infrared spectral range, where it may lead to considerable change in the optimal design of the biosensor.