Related Experiment Video
Updated: Aug 31, 2025

Highly Sensitive Measurement of Glomerular Permeability in Mice with Fluorescein Isothiocyanate-polysucrose 70
Published on: August 9, 2019
Perfluorooctanesulfonate Can Cause Negative Bias in Creatinine Measurement in Hemodialysis Patients Using Polysulfone
Wen-Sheng Liu1,2,3,4,5, Chien-Hung Lin2,3,6, Szu-Yuan Li2,7
1Division of Nephrology, Department of Medicine, Taipei City Hospital Zhongxing Branch, Taipei 103, Taiwan.
Abstract:
Serum creatinine is an important clinical marker for renal clearance. However, two conventional methods (Jaffe and enzymatic) are prone to interferences with organic compounds as compared to the standard method (isotope dilution-liquid chromatography-mass spectrometry) and can cause a significant negative bias. Perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA) are two common perfluorochemicals (PFCs) that can easily be accumulated in humans. We aimed to verify whether this bias is the result of an accumulation of PFCs. The serum creatinine values of 124 hemodialysis patients were analyzed using the three methods. We also aimed to evaluate which biochemical parameters will influence the difference between the conventional methods and the standard method. We found that a significant underestimation occurred when using the conventional methods. Albumin is an independent factor associated with negative bias, but it loses this correlation after dialysis, likely due to the removal of protein-bound uremic toxins. PFOS can cause negative bias when using the enzymatic method. Furthermore, this linear correlation is more significant in patients who used polysulfone-based dialysis membranes, possibly due to the better clearance of other uremic toxins. The serum creatinine of uremic patients can be significantly underestimated when using conventional methods. PFCs, as well the type of dialysis membrane being used, can be influencing factors.
Related Concept Videos
Dialysis
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Peritoneal Dialysis III: Nursing Management
Hemodialysis II: Procedure and Complications

