VERTICAL DOSIMETRIC MEASUREMENT OF ELECTRIC DISCHARGE INDUCED AT LIGHTNING IMPULSE VOLTAGE GENERATOR

Dagmar Štěpánová1,2, Jan Mikeš3, Václav Štěpán1,2

  • 1Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences, 180 00 Prague, Czech Republic.

Related Concept Videos

Van de Graaff Generator01:15

Van de Graaff Generator

Van de Graaff generators (or Van de Graaffs) are devices used to demonstrate high voltage due to static electricity that can also be used for research. Robert Van de Graaff first built one in 1931 (based on original suggestions by Lord Kelvin) for use in nuclear physics research.
Van de Graaff uses both smooth and pointed surfaces, conductors, and insulators to generate large static charges and, hence, large voltages. A substantial excess charge can be deposited on the sphere because it moves...
1.8K
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
214
Galvanometer01:25

Galvanometer

Common devices, including car instrument panels, battery chargers, and inexpensive electrical instruments, measure potential difference (voltage), current, or resistance using a d'Arsonval galvanometer. This electromechanical instrument is also known as a moving coil galvanometer.
The galvanometer consists of  two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
2.3K
Voltammetric Techniques: Pulse Voltammetry01:17

Voltammetric Techniques: Pulse Voltammetry

Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
661
Generator Voltage Control01:21

Generator Voltage Control

Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
235
Voltmeter01:18

Voltmeter

A voltmeter is an electrical device that measures the potential difference or voltage between two points. It is connected in parallel with the circuit element it is measuring. A parallel connection is used because elements in parallel experience the same potential difference. The voltmeter is represented by the symbol "V ".
An ideal voltmeter would have infinite resistance, so connecting it between two points in a circuit would not alter any of the currents. Real voltmeters always have...
1.8K