Related Experiment Video
Updated: Aug 31, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
MODELING AND OPTIMIZATION OF HPGE DETECTOR GC0518 USING MCNP5 CODE
Branislav Stríbrnský1, Róbert Hinca1, Gabriel Farkas1
1Slovak University of Technology in Bratislava, Faculty of Electrical Engineering and Information Technology, Institute of Nuclear and Physical Engineering, Ilkovičova 3, 812 19 Bratislava, Slovakia.
Abstract:
For precise modeling of a high purity germanium (HPGe) detector, detailed knowledge of its geometry is necessary. Unfortunately, some of the detector geometric parameters are often not available. This study suggests simple procedures for determining geometry without the need for radiography. The study considers the HPGe detector GC0518 manufactured by Mirion. The detector datasheet is available, but the uncertainties do not allow the detector to be modeled without additional corrections. The detector was modeled using MCNP5 code and the results were compared with calibration point sources and Marinelli beakers measurements. We also performed measurements to obtain information on the germanium dead layer, crystal holder shape, inner hole shape and radii of the crystal edges. Then the model was optimized according to the measurements. Finally, the full energy peak efficiencies were evaluated. The relative differences between the measured and calculated efficiencies are less than 4.5% for point sources and 5.4% for Marinelli beakers.
More Related Videos
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
11:24High Precision FRET at Single-molecule Level for Biomolecule Structure Determination
Published on: May 13, 2017
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Biasing of P-N Junction
In equilibrium, no external voltage is applied across the p-n junction. The depletion region is formed at the junction interface due to the diffusion of carriers, which leaves behind charged dopants, acceptors on the p-side, and donors on the n-side. These immobile charges create an electric field that prevents further diffusion of carriers. The related energy band...
Norton Equivalent Circuits