Related Experiment Video
Updated: Aug 30, 2025

Point-of-Care Lung Ultrasound in Adults: Image Acquisition
Published on: March 3, 2023
An Evaluation of the Quality of Plain Radiograph Interpretations by Radiology Trainees: A Single Institution
Nurliyana Izyan A Halim1, Faizah Mohd Zaki1,2, Hanani Abdul Manan1,2,3
1Department of Radiology, Universiti Kebangsaan Malaysia Medical Center, Jalan Yaacob Latif, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, Malaysia.
Abstract:
Introduction: The primary communication between the radiologist and referrer is through the radiological report. However, there are incidents of misinterpretation during radiologist training. Therefore, the present study aimed to evaluate the accuracy level and incidence of interpretation errors for plain radiographs among radiology trainees at our institution. Materials and Methods: The present study retrospectively reviewed 508 reported plain radiographs for one year, and two radiologists subsequently evaluated these plain radiographs. The initial diagnosis by the trainee was compared with the radiologists’ evaluation, and the results were categorized as either ‘accurate’, ‘minor discrepancy’, or ‘major discrepancy’. The data were analyzed concerning the overall performance, year of trainee, anatomic area, patient age group, and radiograph type. A chi-square test was performed, with p < 0.05 indicating statistical significance. Results: The overall accuracy rate was 69%, with minor and major discrepancy rates of 21% and 10%, respectively. There was an insignificant increase in overall accuracy with increased years of training, despite a reduction to 58% accuracy among Year 3 trainees. The accuracy level increased between Year 1, Year 2 and Year 4 by 70%, 71% and 75%, respectively (p > 0.05). The accuracy rates for both the adult and pediatric age groups were not statistically significant. The mobile radiographs showed lower accuracy rate of reporting than the plain radiographs. Conclusion: The radiological trainee interpretations for plain radiographs had an average rating with low discrepancy rates. The Year 3 trainees had the lowest accuracy compared to the other trainee groups. However, the present study suggests the need for further research to determine if the current outcomes are outliers or are indicative of a real phenomenon.
More Related Videos
05:04Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Related Concept Videos
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...