Oral anticoagulants (OAC) are recommended for preventing stroke and systemic embolism in atrial fibrillation. Proper use is imperative for maximizing anticoagulation therapy's effectiveness and safety. In preparation for the implementation of a smartphone-based SmartMed app (application) aiming to promote patient self-management, medication adherence, and data collection for patients on anticoagulation therapy, its usability assessment can ensure the value of OAC app development and adoption. We evaluated the SmartMed app's usability using the System Usability Scale (SUS) and the app-specific domain of the Mobile App Rating Scale (MARS) for its perceived impact on taking OAC regularly. We recruited 25 OAC users and their home caregivers and 59 healthcare professionals, including pharmacists, nurses, and cardiac surgeons from one medical center and one regional hospital in Taiwan. All participants (n = 84) thought the SmartMed app was useful, with mean SUS and MARS scores of 81.49 (±14.42) and 4.65 (±0.49), respectively. Usability evaluation revealed that fewer experiences with smartphone apps and different healthcare professionals (pharmacists versus nurses or cardiac surgeons) were associated with lower SUS scores and perceived impact. Throughout the evaluation process, the SmartMed app's design was considered helpful from multiple stakeholders' perspectives. Further ongoing mobile technology supports are necessary to establish the SmartMed app's effectiveness.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment: