Prediction of Neonatal Respiratory Morbidity Assessed by Quantitative Ultrasound Lung Texture Analysis in Twin Pregnancies
Related Experiment Video
Updated: Aug 30, 2025

Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Ana L Moreno-Espinosa1,2,3, Ameth Hawkins-Villarreal1,2,3, David Coronado-Gutierrez1,4
1BCNatal-Fetal Medicine Research Center, Hospital Clínic and Hospital Sant Joan de Déu, Universitat de Barcelona, 08028 Barcelona, Spain.
The objective of this study was to evaluate the performance of quantitative ultrasound of fetal lung texture analysis in predicting neonatal respiratory morbidity (NRM) in twin pregnancies. This was an ambispective study involving consecutive cases. Eligible cases included twin pregnancies between 27.0 and 38.6 weeks of gestation, for which an ultrasound image of the fetal thorax was obtained within 48 h of delivery. Images were analyzed using quantusFLM® version 3.0. The primary outcome of this study was neonatal respiratory morbidity, defined as the occurrence of either transient tachypnea of the newborn or respiratory distress syndrome. The performance of quantusFLM® in predicting NRM was analyzed by matching quantitative ultrasound analysis and clinical outcomes. This study included 166 images. Neonatal respiratory morbidity occurred in 12.7% of cases, and it was predicted by quantusFLM® analysis with an overall sensitivity of 42.9%, specificity of 95.9%, positive predictive value of 60%, and negative predictive value of 92.1%. The accuracy was 89.2%, with a positive likelihood ratio of 10.4, and a negative likelihood ratio of 0.6. The results of this study demonstrate the good prediction capability of NRM in twin pregnancies using a non-invasive lung texture analysis software. The test showed an overall good performance with high specificity, negative predictive value, and accuracy.
The objective of this study was to evaluate the performance of quantitative ultrasound of fetal lung texture analysis in predicting neonatal respiratory morbidity (NRM) in twin pregnancies. This was an ambispective study involving consecutive cases. Eligible cases included twin pregnancies between 27.0 and 38.6 weeks of gestation, for which an ultrasound image of the fetal thorax was obtained within 48 h of delivery. Images were analyzed using quantusFLM® version 3.0. The primary outcome of this study was neonatal respiratory morbidity, defined as the occurrence of either transient tachypnea of the newborn or respiratory distress syndrome. The performance of quantusFLM® in predicting NRM was analyzed by matching quantitative ultrasound analysis and clinical outcomes. This study included 166 images. Neonatal respiratory morbidity occurred in 12.7% of cases, and it was predicted by quantusFLM® analysis with an overall sensitivity of 42.9%, specificity of 95.9%, positive predictive value of 60%, and negative predictive value of 92.1%. The accuracy was 89.2%, with a positive likelihood ratio of 10.4, and a negative likelihood ratio of 0.6. The results of this study demonstrate the good prediction capability of NRM in twin pregnancies using a non-invasive lung texture analysis software. The test showed an overall good performance with high specificity, negative predictive value, and accuracy.
More Related Videos
05:50International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
11:27A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023