How Strong Can We Pull? Critical Thresholds for Traction Forces on the Aortic Annulus: Measurements on Fresh Porcine
Martin Hartrumpf1, Josephine Sterner1, Filip Schroeter1
1Department of Cardiovascular Surgery, Heart Center Brandenburg, University Hospital Brandenburg Medical School (Theodor Fontane), Ladeburger Strasse 17, 16321 Bernau bei Berlin, Germany.
Abstract:
Background and Objectives: Friable or infected tissue remains a challenge in surgical aortic valve replacement. We recently described the "Caput medusae" method, in which circumferential tourniquets temporarily secure the prosthesis and are then gently knotted. Tourniquets have been shown to develop significantly less force than knots. The current study investigates the critical threshold forces for tissue damage to the aortic annulus. Materials and Methods: In 14 fresh porcine hearts, the aortic valve leaflets were removed and several pledgeted sutures were placed along the annulus at defined locations. The hearts were mounted in a self-constructed device. Incremental traction force was applied to every suture and continuously recorded. The movement of each Teflon pledget was filmed with a high-speed camera. Forces at the moment of pledget "cut-in" as well as complete "tear-out" were determined from the recordings. Results: The average threshold force was determined 9.31 ± 6.04 N for cut-in and 20.41 ± 10.02 N for tear-out. Detailed analysis showed that the right coronary region had lower threshold forces than the other regions (4.77 ± 3.28 N (range, 1.67-12.75 N) vs. 10.67 ± 6.04 N (1.62-26.00 N) for cut-in and 10.67 ± 4.04 N (5.40-18.64 N) vs. 23.33 ± 9.42 N (9.22-51.23 N) for tear-out). The findings are discussed in conjunction with the knot and tourniquet forces from our previous study. Conclusions: Even in healthy tissue, moderate forces can reach a critical level at which a Teflon pledget will cut into the annulus, while a complete tear-out is unlikely. The right coronary portion is more susceptible to damage than the remaining regions. When compared to previous data, forces during manual knotting may exceed the critical cut-in level, while rubber tourniquets may provide a higher safety margin against tissue rupture.
More Related Videos
09:24O-Ring Aortic Banding Versus Traditional Transverse Aortic Constriction for Modeling Pressure Overload-Induced Cardiac Hypertrophy
Published on: October 6, 2022
09:32Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
Published on: September 19, 2018
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Bearings: Problem Solving
Aneurysm I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Rolling Resistance
For instance, imagine a hard cylinder rolling on a comparatively soft surface. The cylinder's weight compresses the surface beneath it. As the cylinder moves, the material in front of it slows down...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement