The Corrosion Resistance of Reinforced Magnesium Phosphate Cement Reactive Powder Concrete
Zhiqiang Xu1, Peng Cao2, Di Wang1
1School of Chemical and Mechanical Engineering, Liaodong University, Dandong 118001, China.
Abstract:
Magnesium phosphate cement-based reactive powder concrete (MPC-RPC) is a cement-based material with early strength, high strength and excellent durability. The slump flow and setting time of steel fibers reinforced MPC-RPC are investigated. Meanwhile, the flexural strength, the compressive strength, the ultrasonic velocity and the electrical resistivity of specimens cured for 3 h, 1 day, 3 days and 28 days are determined. Moreover, the corresponding corrosion resistance reinforced MPC-RPC exposing to NaCl freeze-thaw (F-T) cycles and dry-wet (D-W) alternations is researched. In this study, the steel fibers used are 0%, 0.5%, 1.0%, 1.5%, 2.0%, 2.5% and 3.0% by the volume of MPC-RPC. The corrosion of the inner reinforcement is reflected using the mass loss, electrical resistivity, ultrasonic velocity, and the AC impedance spectrum. Researching findings show that the steel fibers lead to decreasing the slump flow and setting time. The flexural strength, the compressive strength and ultrasonic velocity of MPC-RPC cured for 3 h are higher than 45% of the MPC-RPC cured for 28 days. Moreover, when the MPC-RPC is cured for 7 days, the flexural strength, the compressive strength and ultrasonic velocity of MPC-RPC are higher than 85% of the specimens cured for 28 days. The electrical resistance decreases in a quadratic function as the volume ratio of steel fibers increases. The corrosion resistance of the internal reinforcement can be improved by adding steel fibers at appropriate dosages. The reinforcement inner MPC-RPC corrodes more seriously under the NaCl D-W alternations than NaCl F-T cycles.
More Related Videos
10:24Applicability Analysis of Assessment Methods for Morphological Parameters of Corroded Steel Bars
Published on: November 1, 2018
06:27Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Related Concept Videos
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Fiber Reinforced Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...
Acid Attack on Concrete
The rate at which hydrogen...
Frost Resistant Concrete
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...