Change of the Structural Properties of High-Performance Concretes Subjected to Thermal Effects
Grzegorz Piotr Kaczmarczyk1, Daniel Wałach1, Eduardo Natividade-Jesus2,3
1Department of Geomechanics, Civil Engineering and Geotechnics, The Faculty of Civil Engineering and Resource Management, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, Poland.
Abstract:
The paper refers to studies of the structure of high-performance concrete with polypropylene fibre at different dosages. The authors see a research gap in the study of the effect of adding polypropylene fibre on the parameters of concrete exposed to high temperatures. The study takes into account the thermal effect-groups of samples were heated to 200 °C, 400 °C and 600 °C. The authors carried out basic tests to describe the changes in density, ultrasonic tests, uniaxial compression strength tests and tensile tests by splitting. The positive effect of polypropylene fibres is mainly observed between 20 °C and 200 °C. The melting of polypropylene fibres causes a delay in the development of micro-cracks in the structure of these concretes compared to HPC. Adding polypropylene fibres to the mixtures also increased the speed of ultrasonic wave propagation in the medium. The research was deepened with tomographic imaging. A description of the splitting surface was carried out. The results of tensile by splitting tests clearly show an increase in the relative failure area for unheated concretes in proportion to the number of fibres used. Changes in splitting surfaces under the influence of temperature are graphically illustrated. Furthermore, differences in the samples under the influence of heating at high temperatures are presented. Finally, the porosity development of all sample groups before and after heating at all temperatures is described.
More Related Videos
10:52Conducting Elevated Temperature Normal and Combined Pressure-Shear Plate Impact Experiments Via a Breech-end Sabot Heater System
Published on: August 7, 2018
06:27Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Related Concept Videos
Mass Concreting
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
Cold Weather Concreting
To counteract the negative impacts of cold weather, ensuring...
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Effects of Air-entrainment in Concrete