Related Experiment Video
Updated: Aug 30, 2025

Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions
Published on: July 22, 2013
Rapid and Sensitive Electrochemical Assay of Cefditoren with MWCNT/Chitosan NCs/Fe2O3 as a Nanosensor
Nida Aydogdu1,2, Goksu Ozcelikay2, Sibel A Ozkan2
1Department of Analytical Chemistry, Faculty of Pharmacy, Afyonkarahisar Health Sciences University, Afyonkarahisar 03218, Turkey.
Abstract:
In this research, a glassy carbon electrode (GCE) modified by MWCNT/chitosan NCs/Fe2O3 was prepared for the determination of the cephalosporin antibiotic cefditoren (CFT) using adsorptive stripping differential pulse and cyclic voltammetry techniques. The effects of pH, the scan rate, the deposition potential, the accumulation time, and modification agents on the determination of CFT were analyzed. The results showed that the modified electrode significantly increased the oxidation peak current of CFT. Under optimized conditions, the MWCNT/chitosan NCs/Fe2O3/GCE nanosensor exhibited a linear response between 0.2 µM and 10 µM toward CFT. The limit of detection and quantification were determined to be 1.65 nM and 5.50 nM, respectively. Model drugs (cefdinir, cefpodoxime, cephalexin, and ceftazidime compounds) were used to enlighten the CFT oxidation mechanism. Moreover, the nanosensor was used to analyze CFT in a pharmaceutical dosage form and commercial deproteinated human serum samples. The accuracy of these methods was proven in the recovery studies, with values of 96.98 and 98.62% for the pharmaceutical dosage form and commercial deproteinated human serum sample, respectively.