Related Experiment Video
Updated: Aug 30, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Atrioventricular Synchronization for Detection of Atrial Fibrillation and Flutter in One to Twelve ECG Leads Using a
Irena Jekova1, Ivaylo Christov1, Vessela Krasteva1
1Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str. Bl 105, 1113 Sofia, Bulgaria.
Abstract:
This study investigates the use of atrioventricular (AV) synchronization as an important diagnostic criterion for atrial fibrillation and flutter (AF) using one to twelve ECG leads. Heart rate, lead-specific AV conduction time, and P-/f-wave amplitude were evaluated by three representative ECG metrics (mean value, standard deviation), namely RR-interval (RRi-mean, RRi-std), PQ-interval (PQi-mean, PQI-std), and PQ-amplitude (PQa-mean, PQa-std), in 71,545 standard 12-lead ECG records from the six largest PhysioNet CinC Challenge 2021 databases. Two rhythm classes were considered (AF, non-AF), randomly assigning records into training (70%), validation (20%), and test (10%) datasets. In a grid search of 19, 55, and 83 dense neural network (DenseNet) architectures and five independent training runs, we optimized models for one-lead, six-lead (chest or limb), and twelve-lead input features. Lead-set performance and SHapley Additive exPlanations (SHAP) input feature importance were evaluated on the test set. Optimal DenseNet architectures with the number of neurons in sequential [1st, 2nd, 3rd] hidden layers were assessed for sensitivity and specificity: DenseNet [16,16,0] with primary leads (I or II) had 87.9-88.3 and 90.5-91.5%; DenseNet [32,32,32] with six limb leads had 90.7 and 94.2%; DenseNet [32,32,4] with six chest leads had 92.1 and 93.2%; and DenseNet [128,8,8] with all 12 leads had 91.8 and 95.8%, indicating sensitivity and specificity values, respectively. Mean SHAP values on the entire test set highlighted the importance of RRi-mean (100%), RR-std (84%), and atrial synchronization (40-60%) for the PQa-mean (aVR, I), PQi-std (V2, aVF, II), and PQi-mean (aVL, aVR). Our focus on finding the strongest AV synchronization predictors of AF in 12-lead ECGs would lead to a comprehensive understanding of the decision-making process in advanced neural network classifiers. DenseNet self-learned to rely on a few ECG behavioral characteristics: first, characteristics usually associated with AF conduction such as rapid heart rate, enhanced heart rate variability, and large PQ-interval deviation in V2 and inferior leads (aVF, II); second, characteristics related to a typical P-wave pattern in sinus rhythm, which is best distinguished from AF by the earliest negative P-peak deflection of the right atrium in the lead (aVR) and late positive left atrial deflection in lateral leads (I, aVL). Our results on lead-selection and feature-selection practices for AF detection should be considered for one- to twelve-lead ECG signal processing settings, particularly those measuring heart rate, AV conduction times, and P-/f-wave amplitudes. Performances are limited to the AF diagnostic potential of these three metrics. SHAP value importance can be used in combination with a human expert's ECG interpretation to change the focus from a broad observation of 12-lead ECG morphology to focusing on the few AV synchronization findings strongly predictive of AF or non-AF arrhythmias. Our results are representative of AV synchronization findings across a broad taxonomy of cardiac arrhythmias in large 12-lead ECG databases.
More Related Videos
09:17High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias II: Classification of Tachyarrhythmias
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias III: Characteristics of Dysrhythmias