Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
A Hierarchical Network with Fault Tolerance by a Multi-Factor Method for Neighborhood Area Network in Smart Grid
Jiatao Du1, Xiaohui Li1,2, Jie He1,2
1School of Information Science and Engineering, Wuhan University of Science and Technology, Wuhan 430081, China.
Abstract:
The neighborhood area network of a smart grid usually has hierarchical wireless communication. Due to forwarding and processing more data, the upper-layer nodes are more likely to suffer congestion and energy exhaustion. This phenomenon leads to the failure of uploading data to the control center. To solve this problem, this paper proposes a scheme for constructing a multi-factor fault-tolerant hierarchical network. This scheme firstly defines a criterion for the generation of redundant links by multi-factor method in a hierarchical wireless network with the characteristics of the neighborhood area network. Then the redundant links are used to reconstruct the existing topology of the neighborhood area network for improving fault tolerance. Finally, a greedy routing algorithm is put forward to select a proper data transmission path by bypassing low energy nodes, further reducing the failure of uploading data to the control center. The simulation results show that the proposed scheme can effectively improve the fault tolerance of the network topology of the wireless neighborhood area network and balance the network energy consumption. Compared with the original scheme, the proposed scheme improves the fault tolerance by 35% and the relative transmission rate by 21%.
Related Concept Videos
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Secondary Distribution
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
Distribution Reliability and Automation
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...