Quantitation of Enantiomeric Excess in an Achiral Environment Using Trapped Ion Mobility Mass Spectrometry

Joseph Czekner1, Erik K Schneider1, Patrick Weis1

  • 1Institute of Physical Chemistry (IPC), Karlsruhe Institute of Technology (KIT), Fritz-Haber Weg 2, 76131 Karlsruhe, Germany.

Related Concept Videos

Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
692
Racemic Mixtures and the Resolution of Enantiomers02:30

Racemic Mixtures and the Resolution of Enantiomers

A racemic mixture, or racemate, is an equimolar mixture of enantiomers of a molecule that can be separated using their unique interaction with chiral molecules or media. Racemic mixtures are denoted by the (±)- prefix. This ‘optical rotation descriptor’ applies to the whole solution of a racemic mixture rather than a specific stereoisomer. Enantiomers typically have the same physical and chemical properties. Hence, they are not easily separable. However, enantiomers can exhibit...
18.6K
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
1.1K
Properties of Enantiomers and Optical Activity02:24

Properties of Enantiomers and Optical Activity

It is essential to understand the difference between chiral and achiral interactions and the implications thereof in optical activity and their applications. Just as our feet, which are chiral, interact uniquely with chiral objects, such as a pair of shoes, but identically with achiral socks, enantiomers of a molecule exhibit different properties only when they interact with other chiral media. An example of a significant implication from this facet is the phenomenon known as optical activity,...
17.4K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
790
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.5K