Related Experiment Video
Updated: Aug 30, 2025

In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
Published on: May 30, 2020
Analysis of thermocouple-based finger contact temperature measurements
Konrad Rykaczewski1, Tanmay Dhanote1
1School for Engineering of Matter, Transport and Energy, Arizona State University, 501 E Tyler Mall, Tempe, AZ, 85287, USA.
Abstract:
The understanding of heat conduction during finger contact with cooler or hotter objects is important for designing many electronic devices and for setting safety standards in a variety of occupational settings. In the most common experimental approach to study this process, a micro-thermocouple is placed at the finger-object interface. However, the interpretation of what this measurement corresponds to is not clear. To this end, we develop a three-dimensional thermal simulation of the finger-thermocouple-substrate configuration. The model predictions match finger cooling measurements in eight distinct cases available in prior literature (finger pressed with 1 N or 9.8 N against a steel or an aluminum substrate held at -2 °C or -10 °C). We demonstrate that the thermocouple can be represented accurately as a truncated sphere with emerging cylindrical wires while a multilayer block model of the finger provides similar results to an anatomically representative model. Our simulations show that in the eight previously studied cooling cases, the average surface temperature of skin that is in contact with the substrate follows nearly the same but offset cooling trend as the thermocouple tip temperature. The value of the offset is predominantly determined by the substrate material, with the thermocouple tip temperature being lower than the average skin surface temperature by 1-5 °C and 3-10 °C for steel and aluminum substrate cases, respectively. This temperature difference results in a moderate to an extreme thermocouple underprediction of the time necessary for the skin surface to reach the experimental safety threshold of 1 °C. Consequently, from the perspective of the safety related applications the thermocouple measurement provides a conservative limit on the contact duration and thereby is suitable for such purposes, but for applications requiring accurate skin temperature measurements alternative experimental approaches should be used.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...