Related Experiment Video
Updated: Aug 30, 2025

Low-Cost Single-Port LoCoSP Device for a Transcervical Approach in Minimally Invasive Transhiatal Esophagectomy
Published on: September 11, 2021
Use of a Video Laryngoscope to Reduce Complications of Transesophageal Echocardiography Probe Insertion: A
Deepak Borde1, Kumar C2, Amish Jasapara3
1Department of Cardiac Anesthesia, Ozone Anesthesia Group, Aurangabad, Maharashtra, India.
Objective:
The objective of this multicenter study was to test the hypothesis of whether the use of a video laryngoscope (VL) reduces complications related to transesophageal echocardiography (TEE) probe insertion.
Design:
A multicenter randomized control study.
Setting:
At 5 tertiary care level hospitals.
Participants:
Three hundred sixty-three adult patients undergoing elective cardiac surgery.
Interventions:
The patients were randomized into 2 groups-the conventional group (C group; n = 177) and the VL group (n = 186) for TEE probe insertion.
Measurements And Main Results:
The primary endpoint of the study was the incidence of oropharyngeal injury, which was defined as blood at the tip of the TEE probe at the end of surgery and/or evidence of injury on VL examination at the end of surgery. The secondary endpoints of the study were the number of attempts required for successful TEE probe insertion and the relation between the esophageal inlet and the larynx. There was a higher incidence of injuries in the C group (n = 26; 14.7%) compared to the VL group (n = 14; 7.5%; p = 0.029). The number of attempts for probe insertion was significantly lower in the VL group (p = 0.0023). The most common relation between the esophageal inlet and the larynx was posterolateral (n = 88; 47%), followed by posterior (n = 77; 41%) and lateral (n = 21;12%).
Conclusion:
The use of VL was associated with a lesser incidence of injury compared to the conventional technique, and its use for this purpose is recommended. The use of VL for probe insertion resulted in fewer attempts compared with the conventional technique. Significant variations do exist in the relation between the esophageal inlet and the larynx, and direct visualization with VL may contribute to better safety.
More Related Videos
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures V: ERCP
Patient...