Effects of Mechanical Insufflation-Exsufflation With Different Pressure Settings on Respiratory Mucus Displacement
Joan-Daniel Martí1, Roberto Martínez-Alejos2, Xabier Pilar-Diaz3
1Cardiac Surgery Critical Care Unit, Institut Clinic Cardiovascular, Hospital Clínic, Barcelona, Spain; and Institut d'Investigacions Biomèdiques August Pi i Sunyer, Barcelona, Spain.
Background:
Mechanical insufflation-exsufflation (MI-E) has been proposed as a potential strategy to generate high expiratory flows and simulate cough in the critically ill. However, efficacy and safety of MI-E during invasive mechanical ventilation are still to be fully elucidated. This study in intubated and mechanically ventilated pigs aimed to evaluate the effects of 8 combinations of insufflation-exsufflation pressures during MI-E on mucus displacement, respiratory flows, as well as respiratory mechanics and hemodynamics.
Methods:
Six healthy Landrace-Large White female pigs were orotracheally intubated, anesthetized, and invasively ventilated for up to 72 h. Eight combinations of insufflation-exsufflation pressures (+40/-40, +40/-50, +40/-60, +40/-70, +50/-40, +50/-50, +50/-60, +50/-70 cm H2O) were applied in a randomized order. The MI-E device was set to automatic mode, medium inspiratory flow, and an inspiratory-expiratory time 3 and 2 s, respectively, with a 1-s pause between cycles. We performed 4 series of 5 insufflation-exsufflation cycles for each combination of pressures. Velocity and direction of movement of a mucus simulant containing radio-opaque markers were assessed through sequential lateral fluoroscopic images of the trachea. We also evaluated respiratory flows, respiratory mechanics, and hemodynamics before, during, and after each combination of pressures.
Results:
In 3 of the animals, experiments were conducted twice; and for the remaining 3, they were conducted once. In comparison to baseline mucus movement (2.85 ± 2.06 mm/min), all insufflation-exsufflation pressure combinations significantly increased mucus velocity (P = .01). Particularly, +40/-70 cm H2O was the most effective combination, increasing mucus movement velocity by up to 4.8-fold (P < .001). Insufflation pressure of +50 cm H2O resulted in higher peak inspiratory flows (P = .004) and inspiratory transpulmonary pressure (P < .001) than +40 cm H2O.
Conclusions:
MI-E appeared to be an efficient strategy to improve mucus displacement during invasive ventilation, particularly when set at +40/-70 cm H2O. No safety concerns were identified although a transient significant increase of transpulmonary pressure was observed.
More Related Videos
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Cycle: Exhalation