Edson J L Moreira1, Emmanuel J N L Silva1, Felipe G Belladonna1

  • 1Department of Endodontics; Fluminense Federal University (UFF); Niterói; RJ; Brazil.

Brazilian Dental Journal
|August 31, 2022
PubMed
Summary

Heat treatment of ProFile nickel-titanium instruments enhances cyclic fatigue resistance. However, this improvement comes at the cost of reduced flexibility and buckling resistance, impacting overall mechanical performance.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Reciprocating Kinematics in Endodontics: 18 Years of Scientific Evolution and Global Research Trends.

International endodontic journal·2026
Same authorSame journal

Three-Dimensional Evaluation of Accessory Canals in Primary Maxillary Molars Using Micro-CT.

Brazilian dental journal·2026
Same author

Chronic Stress Predictability Modulates the Severity of Apical Periodontitis Induced in Wistar Rats.

International endodontic journal·2026
Same author

The GentleWave System: A Wave of Innovation in Search of Evidence.

European endodontic journal·2026
Same author

Influence of Heat Treatment on the Shaping Ability of Rotary Instruments in Severely Curved Root Canals: A Stepwise Analysis.

European endodontic journal·2026
Same author

Redefining the Evolution of Pulpal Pathology: Inflammasomes as Central Integrative Hubs and Biological Switches Governing the Transition From Reversible to Irreversible Pulpal Inflammation Beyond Symptom-Based Classification.

International endodontic journal·2026

Area of Science:

  • Materials Science
  • Biomaterials Engineering
  • Dental Materials

Background:

  • Nickel-titanium (NiTi) instruments are widely used in endodontics.
  • Understanding the impact of heat treatment on NiTi instrument properties is crucial for clinical success.
  • ProFile instruments are a common type of NiTi rotary files used in root canal preparation.

Purpose of the Study:

  • To investigate the effects of two distinct heat treatments on the mechanical performance of ProFile NiTi instruments.
  • To compare the cyclic fatigue, bending, and buckling resistance of heat-treated versus conventional ProFile instruments.

Main Methods:

  • ProFile instruments (size 25, 0.06 taper) underwent heat treatment at 450°C or 500°C in an argon atmosphere.
  • Treated and untreated instruments were subjected to cyclic fatigue, bending, and buckling resistance tests.

Related Experiment Videos

  • Fracture surfaces were analyzed using scanning electron microscopy.
  • Statistical analysis was performed using One-way ANOVA and Student-Newman-Keuls tests.
  • Main Results:

    • Heat treatment at 450°C (yellowish) and 500°C (blueish) altered instrument coloration.
    • Conventional instruments exhibited lower cyclic fatigue but higher bending and buckling resistance.
    • Heat-treated instruments (especially at 500°C) demonstrated increased cyclic fatigue resistance.
    • Conversely, heat-treated instruments showed reduced bending and buckling resistance.

    Conclusions:

    • Heat treatment significantly enhances the cyclic fatigue resistance of ProFile NiTi instruments.
    • The observed improvements in cyclic fatigue resistance are associated with decreased flexibility and buckling resistance.
    • Clinicians should consider the trade-offs between cyclic fatigue and flexibility when selecting heat-treated NiTi instruments.