Related Experiment Video
Updated: Aug 30, 2025

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Automated Segmentation of the Systolic and Diastolic Phases in Wrist Pulse Signal Using Long Short-Term Memory
Lin Huang1, Jianjun Yan1, Shiyu Cai1
1Institute of Intelligent Perception and Diagnosis, School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China.
Purpose:
Single-period segmentation is one of the important steps in time-domain analysis of pulse signals, which is the basis of time-domain feature extraction. The existing single-period segmentation methods have the disadvantages of generalization, reliability, and robustness.
Method:
This paper proposed a period segmentation method of pulse signals based on long short-term memory (LSTM) network. The preprocessing was performed to remove noises and baseline drift of pulse signals. Thus, LabelMe was used to label each period of the pulse signals into two parts according to the location of the starting point of main wave and the dicrotic notch, and the dataset of the pulse signal period segmentation was established. Consequently, the labeled dataset was input into the LSTM for training and testing, and the results were compared with sum slope function method.
Result:
The remarkable result with the whole period segmentation accuracy of 92.8% was achieved for the segmentation of seven types of pulse signals. And the segmentation accuracies of the systolic phase, diastolic phase, and whole period using this method were higher than those of the sum slope function method.
Conclusion:
LSTM-based pulse signal segmentation method can achieve outstanding, robust, and reliable segmentation effects of the systolic phase, diastolic phase, and whole period of pulse signals. The research provides a new idea and method for the segmentation of pulse signals.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring pulse

