Related Experiment Video
Updated: Aug 30, 2025

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Maxillary sinus volume in patients with canted occlusal plane: A cone-beam computed tomography study
Nadia K Awad1, Hussain Y A Marghalani2, Mohammed A Barayan3
1Private practice, Jeddah, Saudi Arabia.
Objectives:
To compare the maxillary sinus volume between both sides in adult patients with upper occlusal canting (>2 mm cant) and a control group (≤2 mm cant) using cone-beam computed tomography scans.
Materials And Methods:
This retrospective study included a total of 84 scans (42 scans per group) according to predetermined selection criteria. OnDemand 3-D™ software was used for volumetric and linear measurements of the maxillary sinus. Maxillary occlusal canting was determined at the level of the maxillary first molars. It was defined as the vertical difference between right and left sides relative to the Frankfort horizontal plane. Non-parametric tests were applied.
Results:
The median difference in the maxillary sinus volume between the sides was statistically significant between the control and cant groups (P < 0.001). Also, the median difference in the maxillary sinus craniocaudal height and apex sinus distance between the sides was statistically significant between the control and cant groups (P < 0.05 and P < 0.001, respectively).
Conclusion:
In adult patients, maxillary occlusal canting of more than 2 mm was associated with asymmetric maxillary sinus volumes. In the cant group, maxillary first molars on the canted-down side were in close proximity to the sinus floor, which suggests a limited leeway for molar intrusion.