Related Experiment Video
Updated: Aug 30, 2025

Three-Dimensional Reconstruction of Orbital Fractures
Published on: May 16, 2025
Cyst formation and bony ingrowth inside coil-type open-architecture anchors used for arthroscopic remplissage: a
Miguel Angel Ruiz Ibán1, Irene Zarcos2, Rosa Vega2
1Shoulder and Elbow Unit, Orthopaedic Surgery and Trauma Service, Hospital Universitario Ramón y Cajal, Madrid, Spain; Departamento de Cirugía, Ciencias Sanitarias Y Medicosociales, Alcalá de Henares, Universidad de Alcalá, Madrid, Spain; Departamento de Ciencias Médicas Clínicas, Universidad CEU San Pablo, Madrid, Spain.
Background:
The use of anchors in the proximal humerus during arthroscopic surgery can cause localized bone loss due to osteolysis and cyst formation. The purpose of this study was to use computed tomography (CT) to evaluate the incidence of implant-related bone loss and cyst formation after implantation of polyetheretherketone (PEEK) coil-type open-architecture anchors during remplissage for the management of Hill-Sachs defects (HSDs) in patients with shoulder instability.
Methods:
This was a single-cohort, observational study with a minimum of 12 months of follow-up. Subjects undergoing arthroscopic instability surgery with HSD requiring remplissage were included. The volume of the bone defects and the degree of bony ingrowth into the anchor were measured on CT images.
Results:
Thirty-one participants (28 males, 3 females; mean age 29.4 years, standard deviation [SD] 10.6) in whom 50 anchors (4.5-mm Healicoil PEEK double-loaded anchors) were used were evaluated with a CT performed at a mean of 14.1 (SD 3.74) months after surgery. Full bony ingrowth inside the anchor was found in 15 anchors (30%, range 17.8%-44.5%); clear ossification with a thin lucent rim was found in 10 anchors (20%, range 10.0%-33.7%); discontinuous ossification was found in 8 anchors (16%, range 7.2%-29.1%); and no ossification was observed inside 17 anchors (34%, range 21.2%-48.7%). Regarding bone defect size, no bone defect was identified in 15 anchors (30%, 95% CI 17.9%-44.6%), a partial bone defect was found in 17 anchors (34%, 95% CI 21.2%-48.7%), hole enlargement was found in 17 anchors (34%, 95% CI 21.2%-48.7%), and 1 anchor caused a cyst larger than twice the size of the hole made for anchor insertion (2%, 95% CI 0.1%-8.6%). At the 1-year evaluation, none of the participants presented recurrence or residual apprehension.
Conclusion:
The use of PEEK coil-type open-architecture anchors for remplissage during instability surgery caused large cystic lesions in less than 10% of anchors. There was full bony ingrowth in one-third of anchors, and partial cancellous bone ingrowth occurred in another third of anchors.
More Related Videos
13:16Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015
12:39DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
Published on: September 28, 2021
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bone Remodeling
Bone Formation by Endochondral Ossification