Related Experiment Video
Updated: Aug 30, 2025

Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Comparison of AliveCor KardiaMobile Six-Lead ECG with Standard ECG in Pediatric Patients
Zachary P Girvin1, Eric S Silver2, Leonardo Liberman3
1Vagelos College of Physicians and Surgeons, Columbia University, New York, NY, USA.
Abstract:
The AliveCor KardiaMobile (ACKM) is a remote electrocardiogram (ECG) monitoring device. Little research has been conducted on its accuracy with pediatric patients. This prospective study aims to compare the ACKM six-lead device with a standard fifteen-lead ECG in measuring the QTc, QRS, and axis in pediatric patients. Pediatric patients ages 5 to 21 years were enrolled prospectively to have their ECG recorded using an ACKM six-lead device following a recording with the standard 15-lead ECG. A pediatric electrophysiologist measured the QTc, QRS interval, and QRS axis for both ECGs. Bland-Altman analysis was performed to assess agreement among measurements. The study included 141 patients. The mean age was 12.3 ± 4.4 years. Average heart rate was 79 ± 16 bpm. The mean difference in the QTc measurements for a paired standard ECG and ACKM was - 0.6 ms [95% confidence interval - 48 to 47 ms]. Of the ACKM QTc measurements, 117 (83%) were within 30 ms of the standard ECG. The mean difference in paired QRS measurements was - 1.3 ms [95% confidence interval - 23 to 21 ms]. Of the ACKM QRS measurements, 134 (95%) were within 20 ms of the standard ECG. The measured axis was the same for 84% of ACKM and standard ECGs. Over 80% of the ACKM six-lead ECGs produced QTc, QRS, and axis deviation measurements within a clinically useful range of the standard ECG. However, it is not accurate enough to be used consistently in place of a standard ECG for QTc and QRS measurement for pediatric patients.
More Related Videos
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....