Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Left ventricular volume and ejection fraction measurements by fully automated 3D echocardiography left chamber
Victor Chien-Chia Wu1, Tetsuji Kitano2, Pao-Hsien Chu1
1Division of Cardiology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan City, Taiwan.
Background:
Although transthoracic three-dimensional echocardiography (3DE) is now recommended by guidelines for left ventricular (LV) volumetric measurements, widespread implementation has been limited due to time constraints and required expertise. We hypothesized that fully automated 3DE left chamber quantification software might provide accurate measurements, and that its application could eliminate these obstacles.
Methods:
To address this hypothesis, we conducted a systematic review and meta-analysis following a search for studies that compared LV volumes and ejection fraction (EF) using fully automated 3DE software (HeartModel or Dynamic HeartModel, Philips Healthcare, Andover, MA, USA) with cardiac magnetic resonance (CMR), from 2015 to 2021. A random effects model was used to determine biases, correlations, and 95 % confidence intervals (CI) of LV end-diastolic volume (EDV), end-systolic volume (ESV), and EF. Subgroup and meta-regression analyses were performed to determine effects of moderators on the outcome.
Results:
Of 12 studies (616 subjects), mean differences and 95 % CIs in EDV, ESV, and EF between fully automated 3DE software and CMR were -19.6 mL (95 % CI; -27.6 to -11.5 mL), -11.4 mL (-16.7 to -6.2 mL), and 0.4 % (-1.1 to 2.0 %), respectively. Corresponding correlation values between the two methods were 0.91 (0.86-0.94), 0.89 (0.82-0.93), and 0.85 (0.81-0.88), respectively. Meta-regression analysis revealed that there were no effects of either publication year, type of software, or type of analysis on the outcome of LV volumetric and functional parameters except for publication year on LVESV correlation values.
Conclusions:
Although 3DE still underestimates LV volumes, the observed differences were no >20 mL. EF showed similar values to CMR. Excellent correlations between the two techniques make fully automated 3DE left chamber quantification software useful for routine clinical practice in adult population.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...