Related Experiment Video
Updated: Aug 29, 2025

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Assessing a novel second generation laryngeal mask airway using the 'ADEPT' approach: results from the LMA®
A Ní Eochagáin1, V Athanassoglou2, A Cumberworth2
1Consultant Anaesthetist St. James's Hospital, Dublin, Ireland.
Abstract:
To address the problem of lack of clinical evidence for airway devices introduced to the market, the Difficult Airway Society (UK) developed an approach (termed ADEPT; Airway Device Evaluation Project Team) to standardise the model for device evaluation. Under this framework we assessed the LMA Protector, a second generation laryngeal mask airway. A total of 111 sequential adult patients were recruited and the LMA Protector inserted after induction of general anaesthesia. Effective insertion was confirmed by resistance to further distal movement, manual ventilation, and listening for gas leakage at the mouth. The breathing circuit was connected to the airway channel and airway patency confirmed with manual test ventilation at 20 cm H20 (water) pressure for 3 s. Data was collected in relation to the time for placement, intraoperative performance and postoperative performance of the airway device. Additionally, investigators rated the ease of insertion and adequacy of lung ventilation on a 5-point scale. The median (interquartile range [range]) time taken to insertion of the device was 31 (26-40[14-780]) s with the ability to ventilate after device insertion 100 (95% CI 96.7- 100)%. Secondary endpoints included one or more manoeuvres 60.3 (95% CI 50.6-69.5)% cases requiring to assist insertion; a median ease of insertion score of 4 (2-5[3-5]), and a median adequacy of ventilation score of 5 (5-5[4-5]). However, the first time insertion rate failure was 9.9% (95% CI 5.1-17.0%). There were no episodes of patient harm recorded, particularly desaturation. The LMA Protector appears suitable for clinical use, but an accompanying article discusses our reflections on the ADEPT approach to studying airway devices from a strategic perspective.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...