Related Experiment Video
Updated: Aug 29, 2025

Three-dimensional Location Approach with Silk Thread Guided Laparoscopic Segmentectomy for Liver Tumor
Published on: May 23, 2025
Artificial intelligence for identification of focal lesions in intraoperative liver ultrasonography
Yiftach Barash1, Eyal Klang1, Adar Lux1
1Department of Radiology, Sheba Medical Center, Tel-Hashomer, Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
Purpose:
Intraoperative ultrasonography (IOUS) of the liver is a crucial adjunct in every liver resection and may significantly impact intraoperative surgical decisions. However, IOUS is highly operator dependent and has a steep learning curve. We describe the design and assessment of an artificial intelligence (AI) system to identify focal liver lesions in IOUS.
Methods:
IOUS images were collected during liver resections performed between November 2020 and November 2021. The images were labeled by radiologists and surgeons as normal liver tissue versus images that contain liver lesions. A convolutional neural network (CNN) was trained and tested to classify images based on the labeling. Algorithm performance was tested in terms of area under the curves (AUCs), accuracy, sensitivity, specificity, F1 score, positive predictive value, and negative predictive value.
Results:
Overall, the dataset included 5043 IOUS images from 16 patients. Of these, 2576 were labeled as normal liver tissue and 2467 as containing focal liver lesions. Training and testing image sets were taken from different patients. Network performance area under the curve (AUC) was 80.2 ± 2.9%, and the overall classification accuracy was 74.6% ± 3.1%. For maximal sensitivity of 99%, the classification specificity is 36.4 ± 9.4%.
Conclusions:
This study provides for the first time a proof of concept for the use of AI in IOUS and show that high accuracy can be achieved. Further studies using high volume data are warranted to increase accuracy and differentiate between lesion types.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...