Impact of metal artifact reduction algorithm on gross tumor volume delineation in tonsillar cancer: reducing the
Yoshiyuki Fukugawa1, Ryo Toya2, Tomohiko Matsuyama1
1Department of Radiation Oncology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto, 860-8556, Japan.
Background:
Patients with tonsillar cancer (TC) often have dental fillings that can significantly degrade the quality of computed tomography (CT) simulator images due to metal artifacts. We evaluated whether the use of the metal artifact reduction (MAR) algorithm reduced the interobserver variation in delineating gross tumor volume (GTV) of TC.
Methods:
Eighteen patients with TC with dental fillings were enrolled in this study. Contrast-enhanced CT simulator images were reconstructed using the conventional (CTCONV) and MAR algorithm (CTMAR). Four board-certified radiation oncologists delineated the GTV of primary tumors using routine clinical data first on CTCONV image datasets (GTVCONV), followed by CTCONV and CTMAR fused image datasets (GTVMAR) at least 2 weeks apart. Intermodality differences in GTV values and Dice similarity coefficient (DSC) were compared using Wilcoxon's signed-rank test.
Results:
GTVMAR was significantly smaller than GTVCONV for three observers. The other observer showed no significant difference between GTVCONV and GTVMAR values. For all four observers, the mean GTVCONV and GTVMAR values were 14.0 (standard deviation [SD]: 7.4) cm3 and 12.1 (SD: 6.4) cm3, respectively, with the latter significantly lower than the former (p < 0.001). The mean DSC of GTVCONV and GTVMAR was 0.74 (SD: 0.10) and 0.77 (SD: 0.10), respectively, with the latter significantly higher than that of the former (p < 0.001).
Conclusions:
The use of the MAR algorithm led to the delineation of smaller GTVs and reduced interobserver variations in delineating GTV of the primary tumors in patients with TC.