Related Experiment Video
Updated: Aug 29, 2025

Cardiac Response to β-Adrenergic Stimulation Determined by Pressure-Volume Loop Analysis
Published on: May 19, 2021
Mid-regional plasma pro-atrial natriuretic peptide and stroke volume responsiveness for detecting deviations in
Rune B Strandby1, Niels H Secher2, Rikard Ambrus1
1Department of Surgery and Transplantation, Rigshospitalet, Institute for Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
Background:
A reduced central blood volume is reflected by a decrease in mid-regional plasma pro-atrial natriuretic peptide (MR-proANP), a stable precursor of ANP, and a volume deficit may also be assessed by the stroke volume (SV) response to head-down tilt (HDT). We determined plasma MR-proANP during major abdominal procedures and evaluated whether the patients were volume responsive by the end of the surgery, taking the fluid balance and the crystalloid/colloid ratio into account.
Methods:
Patients undergoing pancreatic (n = 25), liver (n = 25), or gastroesophageal (n = 38) surgery were included prospectively. Plasma MR-proANP was determined before and after surgery, and the fluid response was assessed by the SV response to 10° HDT after the procedure. The fluid strategy was based mainly on lactated Ringer's solution for gastroesophageal procedures, while for pancreas and liver surgery, more human albumin 5% was administered.
Results:
Plasma MR-proANP decreased for patients undergoing gastroesophageal surgery (-9% [95% CI -3.2 to -15.3], p = .004) and 10 patients were fluid responsive by the end of surgery (∆SV > 10% during HDT) with an administered crystalloid/colloid ratio of 3.3 (fluid balance +1389 ± 452 ml). Furthermore, plasma MR-proANP and fluid balance were correlated (r = .352 [95% CI 0.031-0.674], p < .001). In contrast, plasma MR-proANP did not change significantly during pancreatic and liver surgery during which the crystalloid/colloid ratio was 1.0 (fluid balance +385 ± 478 ml) and 1.9 (fluid balance +513 ± 381 ml), respectively. For these patients, there was no correlation between plasma MR-proANP and fluid balance, and no patient was fluid responsive.
Conclusion:
Plasma MR-proANP was reduced in fluid responsive patients by the end of surgery for the patients for whom the fluid strategy was based on more lactated Ringer's solution than human albumin 5%.
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Heart Failure II: Pathophysiology
Hormonal Regulation of Blood Pressure
Epinephrine and Norepinephrine
The adrenal medulla releases epinephrine and norepinephrine, catecholamines that enhance and extend the sympathetic or "fight or flight" physiological response. These hormones escalate heart rate and the force of contraction...
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...