Related Experiment Video
Updated: Aug 29, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Sparse Dictionary-Based Magnetic Resonance Superresolution Imaging with Joint Loss Function Learning
Huanyu Liu1, Xiaodong Liu2, Jinyu Wu3
1Information Countermeasure Technique Institute, School of Computer Science and Technology, Harbin Institute of Technology, Harbin 150080, China.
Abstract:
Magnetic resonance image has important application value in disease diagnosis. Due to the particularity of its imaging mechanism, the resolution of hardware imaging needs to be improved by increasing radiation intensity and radiation time. Excess radiation can cause the body to overheat and, in severe cases, inactivate the protein. This problem is expected to be solved by the image superresolution method based on joint dictionary learning, which has good superresolution performance. In the process of dictionary learning, the loss function will directly affect the dictionary performance. The general method only uses the cascade error as the optimization function in dictionary training, and the method does not consider the individual reconstruction error of high- and low-resolution image dictionary. In order to solve the above problem, In this paper, the loss function of dictionary learning is optimized. While ensuring that the coefficients are sufficiently sparse, the high- and low-resolution dictionaries are trained separately to reduce the error generated by the joint high- and low-resolution dictionary block pair and increase the high-resolution reconstruction error. Experiments on neck and ankle MR images show that the proposed algorithm has better superresolution reconstruction performance on ×2 and ×4 compared with bicubic interpolation, nearest neighbor, and original dictionary learning algorithms.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Super-resolution Fluorescence Microscopy
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
NMR Spectrometers: Resolution and Error Correction

