Related Experiment Video
Updated: Aug 29, 2025

Author Spotlight: A Non-Invasive Tool to Assess and Differentiate Fat Patterns in Liver Using 3D Dixon MRI
Published on: October 20, 2023
Clinical Application of Quantitative CT Technique in Assessing Liver Fat Content in Patients with Schizophrenia
Mengyang Han1, Yilian Lin2, Hong Chen1
1Department of Radiology, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Mdeicine, Shanghai 200030, China.
Abstract:
This paper investigates the clinical application value of quantitative CT (QCT) technique in evaluating liver fat content in patients with schizophrenia. 457 patients with schizophrenia underwent abdominal CT and QCT scans. QCT postprocessing software (QCT Pro version 6.1) measures the percentage of liver fat content in all patients and calculates the average value. Then, the CT workstation displays the corresponding liver/spleen CT value ratio. SPSS 25.0 software is used for statistical analysis of data, and the correlation coefficient between the mean liver fat content. The ratio of liver/spleen CT values is calculated and the consistency between the results is compared. The ROC curve is used to define the cutoff value of the target and evaluate its diagnostic efficiency. There is a high negative correlation between the mean liver fat content and the ratio of liver/spleen CT value in all schizophrenia patients (r = -0.935, P < 0.05). The identification rate of patients with mild fatty liver by QCT technology is 4 times higher than that of the liver and spleen CT value ratio (50.98% Vs 12.47%). Taking the ratio of the liver to the spleen as the standard, the ROC curve of the liver fat content in QCT is drawn, the cutoff values of the mean liver fat content of the normal liver and mild fatty liver and mild and moderate fatty liver were 9.35% and 19.4%, respectively. Comparing this result with the results obtained by the existing QCT for the fatty liver diagnosis and grading standard value (American standard) shows that there is a difference of about 5% between the two. Compared with the semiquantitative liver/spleen ratio, QCT technology can quantify the liver fat content. Given the particularity of patients with schizophrenia, QCT can be used as an important test for identifying early fatty liver and assessing the severity of fatty liver.
More Related Videos
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

