Related Experiment Video
Updated: Jul 12, 2026

An Experimental and Finite Element Protocol to Investigate the Transport of Neutral and Charged Solutes across Articular Cartilage
Published on: April 23, 2017
Establishment of a New Qualitative Evaluation Method for Articular Cartilage by Dynamic T2w MRI Using a Novel
Yoshiaki Hosokawa1, Tomohiro Onodera1, Kentaro Homan1
1Department of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
Objective:
In the early stages of cartilage damage, diagnostic methods focusing on the mechanism of maintaining the hydrostatic pressure of cartilage are thought to be useful. 17O-labeled water, which is a stable isotope of oxygen, has the advantage of no radiation exposure or allergic reactions and can be detected by magnetic resonance imaging (MRI). This study aimed to evaluate MRI images using 17O-labeled water in a rabbit model.
Design:
Contrast MRI with 17O-labeled water and macroscopic and histological evaluations were performed 4 and 8 weeks after anterior cruciate ligament transection surgery in rabbits. A total of 18 T2-weighted images were acquired, and 17O-labeled water was manually administered on the third scan. The 17O concentration in each phase was calculated from the signal intensity at the articular cartilage. Macroscopic and histological grades were evaluated and compared with the 17O concentration.
Results:
An increase in 17O concentration in the macroscopic and histologically injured areas was observed by MRI. Macroscopic evaluation showed that the 17O concentration significantly increased in the damaged site group. Histological evaluations also showed that 17O concentrations significantly increased at 36 minutes 30 seconds after initiating MRI scanning in the Osteoarthritis Research Society International (OARSI) grade 3 (0.493 in grade 0, 0.659 in grade 1, 0.4651 in grade 2, and 0.9964 in grade 3, P < 0.05).
Conclusion:
17O-labeled water could visualize earlier articular cartilage damage, which is difficult to detect by conventional methods.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
06:16A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy
Published on: May 1, 2020