Related Experiment Video
Updated: Aug 29, 2025

Sample Preparation for Probe Electrospray Ionization Mass Spectrometry
Published on: February 19, 2020
Suzuki C-C Coupling in Paper Spray Ionization: Microsynthesis of Biaryls and High-Sensitivity MS Detection of Aryl
Qiuyu Lin1,2, Luyun Xue1, Jiannan Sun1
1College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China.
Abstract:
Suzuki-Miyaura cross-coupling is one of the most powerful strategies for constructing biaryl compounds. However, classic Suzuki-Miyaura coupling suffers from hour-scale reaction time and competitive protodeboronation. To address these problems, a mild nonaqueous potassium trimethylsilanolate (TMSOK)-assisted Suzuki-Miyaura coupling strategy was designed for the microsynthesis of biaryls in paper spray ionization (PSI). Due to the acceleration power facilitated by microdroplet chemistry in reactive PSI, the microsynthesis of biaryls by reactive PSI was accomplished within minutes with comparable yields to the bulk, showing good substrate applicability from 32 Suzuki-Miyaura reactions of aryl bromides and aryl boronic acid/borates bearing different substituents. Based on the above TMSOK-assisted Suzuki-Miyaura coupling strategy, we further developed a high-sensitivity and selective PSI mass spectrometry (MS) method for quantitative analysis of aryl bromides, a class of environmentally persistent organic pollutants that cannot be directly detected by ambient mass spectrometry due to their low ionization efficiency. In situ derivatization of aryl bromides was achieved with aryl borates bearing quaternary ammonium groups in PSI. The proposed PSI-MS method shows good linearity over the 0.01-10 μmol L-1 range with low detection limits of 1.8-4.8 nmol L-1 as well as good applicability to the rapid determination of six aryl bromides in three environmental water samples. The proposed PSI-MS method also shows good applicability to brominated flame retardants (polybrominated diphenyls/diphenyl esters). Overall, this study provides a simple, rapid, low-cost, high-sensitivity, and high-selectivity strategy for trace aryl bromides and other brominated pollutants in real samples with minimal/no sample pretreatment.
More Related Videos
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Atomic Absorption Spectroscopy: Atomization Methods
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...