Measuring Influenza Neutralizing Antibody Responses to AH3N2 Viruses in Human Sera by Microneutralization Assays Using MDCK-SIAT1 Cells
Published on: November 22, 2017
18.2K
Correlation between In Vitro Neutralization Assay and Serological Tests for Protective Antibodies Detection
Maria Addolorata Bonifacio1, Riccardo Laterza1, Angela Vinella1
1Department of Biomedical Sciences and Human Oncology, University of Bari Aldo Moro Medical School, 70124 Bari, Italy.
International Journal of Molecular Sciences
|September 9, 2022
Summary
The EUROIMMUN® NeutraLISA assay shows the strongest correlation with the plaque reduction neutralization test (PRNT) for measuring SARS-CoV-2 neutralizing antibodies. This offers a more accessible alternative for assessing protective immunity against COVID-19.
Area of Science:
- Immunology
- Virology
- Epidemiology
Background:
- Serological assays are crucial for understanding humoral immunity and the spread of protective immunity against SARS-CoV-2.
- The plaque reduction neutralization test (PRNT) is the gold standard for quantifying neutralizing antibodies but is labor-intensive and requires specialized facilities.
- There is a need for alternative, more accessible serological methods that correlate well with PRNT results.
Purpose of the Study:
- To evaluate and compare the performance of four different immunoassays against the PRNT for assessing SARS-CoV-2 neutralizing antibody titers.
- To determine the correlation between commercial immunoassays and the gold standard PRNT.
- To assess the diagnostic accuracy of these assays in identifying high levels of neutralizing antibodies.
Main Methods:
- Four immunoassays (Roche Elecsys®, Snibe MAGLUMI® x2, EUROIMMUN® NeutraLISA) were tested using serum samples from individuals recovered from SARS-CoV-2 infection.
- Linear regression modeling, Pearson’s and Spearman’s correlation coefficients were used to compare assay results with PRNT.
- Receiver operating characteristic (ROC) curve analysis, Cohen’s Kappa, and positive predictive agreement were employed to assess diagnostic performance.
Main Results:
- The EUROIMMUN® NeutraLISA assay demonstrated the highest correlation with PRNT results (Pearson's r=0.660, Spearman's rho=0.784).
- EUROIMMUN® NeutraLISA also exhibited the best performance in ROC curve analysis, with high accuracy (0.857), sensitivity (0.889), and specificity (0.829).
- Other evaluated immunoassays showed varying degrees of correlation and diagnostic accuracy.
Conclusions:
- The EUROIMMUN® NeutraLISA assay is a promising alternative to PRNT for reliable assessment of SARS-CoV-2 neutralizing antibodies.
- This assay offers a more practical approach for epidemiological studies investigating protective immunity against COVID-19.
- Further validation may support its broader use in clinical and public health settings.