Related Experiment Video
Updated: Aug 29, 2025

Diffusion Tensor Magnetic Resonance Imaging in Chronic Spinal Cord Compression
Published on: May 7, 2019
Diagnostic Accuracy of CT for Metastatic Epidural Spinal Cord Compression
James Thomas Patrick Decourcy Hallinan1,2, Shuliang Ge1,2, Lei Zhu3
1Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore.
Background:
Early diagnosis of metastatic epidural spinal cord compression (MESCC) is vital to expedite therapy and prevent paralysis. Staging CT is performed routinely in cancer patients and presents an opportunity for earlier diagnosis.
Methods:
This retrospective study included 123 CT scans from 101 patients who underwent spine MRI within 30 days, excluding 549 CT scans from 216 patients due to CT performed post-MRI, non-contrast CT, or a gap greater than 30 days between modalities. Reference standard MESCC gradings on CT were provided in consensus via two spine radiologists (11 and 7 years of experience) analyzing the MRI scans. CT scans were labeled using the original reports and by three radiologists (3, 13, and 14 years of experience) using dedicated CT windowing.
Results:
For normal/none versus low/high-grade MESCC per CT scan, all radiologists demonstrated almost perfect agreement with kappa values ranging from 0.866 (95% CI 0.787-0.945) to 0.947 (95% CI 0.899-0.995), compared to slight agreement for the reports (kappa = 0.095, 95%CI -0.098-0.287). Radiologists also showed high sensitivities ranging from 91.51 (95% CI 84.49-96.04) to 98.11 (95% CI 93.35-99.77), compared to 44.34 (95% CI 34.69-54.31) for the reports.
Conclusion:
Dedicated radiologist review for MESCC on CT showed high interobserver agreement and sensitivity compared to the current standard of care.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

