Related Experiment Video
Updated: Aug 29, 2025

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
Comparison of Diagnostic Value for Chronic Kidney Disease between 640-Slice Computed Tomography Kidney Scan and
Yusen Zhao1, Yaoyi Wang1, Yuanbo Xu2
1Department of Medical Imaging, The First Affiliated Hospital of Hebei North University, Zhangjiakou City 075000, Hebei Province, China.
Objective:
To explore the diagnostic value for chronic kidney disease (CKD) between 640-slice computed tomography (CT) kidney scan and conventional CT scan.
Methods:
A total of 120 CKD patients who received kidney plain scan plus enhanced examination in the CT room of the Medical Imaging Department of our hospital from June 2019 to September 2019 were selected and randomly divided into the experimental group (n = 60) and the control group (n = 60). Patients in the control group received the conventional CT plain scan and enhanced scan, and for patients in the experimental group, CT plain scan was performed first, the range of 640-slice CT dynamic volume scan was determined, and after bolus injection of contrast agent, dynamic volume scan was performed for scanning in the cortical phase, myeloid phase, and secretory phase. The imaging quality and effective scanning dose were compared between the two modalities, and the relationship between CT values obtained from 640-slice CT scan and conventional CT scan and the renal impairment was analyzed.
Results:
Compared with the control group, the image quality of 640-slice CT scan conducted in the experimental group was significantly better (P < 0.05); the effective radiation doses of the experimental group and the control group were, respectively, (1.89 ± 0.32) mSv and (3.26 ± 0.47) mSv, indicating that the dose was significantly lower in the experimental group than in the control group (t = 18.664, P < 0.001), and the correlation analysis showed that the relationship between the sum of CT values in the cortical phase of both kidneys and kidney injury in the experimental group was r = 0.835, P < 0.001.
Conclusion:
Both 640-slice CT kidney scan and conventional CT scan can be used in the diagnosis of CKD. 640-slice CT has a lower radiation dose, better image quality, and higher application value.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies V: Intravenous Urography and Retrograde Pyelography

