Non-Invasive Radial Artery Blood Pressure Monitoring Using Error Compensated Tactile Sensors and Patient Specific
Abstract:
This paper presents a new method of measuring non-invasive blood pressure at the radial artery based on oscillometry and tonometry. A localized capacitive tactile sensor array is used with a novel algorithm based on waveform features for optimizing oscillometry ratios. A novel tonometer is presented with typically 1% base measurement error, with sensor errors compensated using a custom error model, and applied to blood pressure measurement at the radial artery. The tonometer gives a direct arterial waveform, and uses a manual pressure sweep to determine blood pressure. Key points on the oscillogram are correlated with optimal ratios for minimizing mean errors and standard deviation for an individual. This paper details an initial assessment into the dominant sources of error, for the purpose of determining feasibility and directing future research. Over a limited clinical trial of Np = 20, No = 180, the reported BP accuracy is MAE = 0.61/0.38mmHg and 1SD = 7.14/5.91mmHg for systolic and diastolic measurements respectively. The average load on the patient is in the order of 5N, compared with around 1000N for a brachial cuff, which represents a clear improvement in patient comfort. This is a positive result, indicating larger scale performance within AAMI and BHS standards, and stands as a useful benchmark for further development of the system into a clinical product for rapid and comfortable BP measurement. Clinical Relevance This paper demonstrated that direct tonometry can measure blood pressure if sensor error is compensated by the designer. This method uses 200x less load than conventional cuffs suitable for long term and supine use.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: