Related Experiment Video
Updated: Aug 29, 2025

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Survey, Analysis and Comparison of Radar Technologies for Embedded Vital Sign Monitoring
Abstract:
Contactless vital sign monitoring systems are becoming increasing in demand for a wide range of biomedical applications. Millimetre-wave radars and embedded signal processing are the most promising technologies to enable non-contact vital signs monitoring. In this work, the challenging task of heart rate estimation from radar data has been addressed. Three different radar systems from Infineon, Texas Instruments and Acconeer, and four algorithms, FFT, Median-FFT, STFT and Median-STFT, have been analysed and compared against a reference sensor. Accuracy, as well as power figures, have been reported for all the radar systems. A dataset of 16 volunteers has been acquired, yielding a total of 400 minutes of radar-recorded vital sign data. The accuracy of the four investigated algorithms has been reported on average and per subject for every radar. The algorithm exploiting the Short Time Fourier Transform (STFT) is able to achieve an error as low as 0.02% on a single person and of 6.4% in heart rate estimation on average across the whole dataset.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

