Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
High Frame-Rate A-Mode Ultrasound System for Jugular Venous Pulse Tracking: A Feasibility Study
Abstract:
Jugular venous pulse (JVP) helps in the early detection of central venous pressure abnormalities and various cardiovascular diseases. Studies have been reported indicating that contour features of the JVP waveform provide crucial information regarding cardiac function. Although current ultrasound systems reliably provide the diameter measurements, they are limited by low frame rates resulting in poor resolution JVP cycles that are inadequate to yield distinguishable critical points. In this work, we propose an image-free high frame rate system for the assessment of JVP signals. The proposed A-mode ultrasound system acquires high fidelity JVP pulses with a temporal resolution of 4 ms and amplitude resolution of 10 µm. The functionality verification of the proposed system was performed by comparing it against a clinical-grade B-mode imaging system. A study was conducted on a cohort of 25 subjects in the 20-30 age group. While the system provided diameter measurements comparable to that of the imaging ones (r > 0.98, p < 0.05), it also yielded high-resolution JVP exhibiting the presence of all fiduciary points. This was a leveraging feature as opposed to the imaging system that possessed limited temporal and amplitude resolution. Clinical Relevance- The proposed system is a potential ultrasound means for measuring the diameter values from JV at the same time yielding the JVP critical points necessary for clinical analysis.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...