Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Evaluating the Empatica E4 Derived Heart Rate and Heart Rate Variability Measures in Older Men and Women
Abstract:
Wearable heart rate monitors offer a cost-effective way of non-invasive, long-term monitoring of cardiac health. Validation of wearable technologies in an older populations is essential for evaluating their effectiveness during deployment in healthcare settings. To this end, we evaluated the validity of heart rate measures from a wearable device, Empatica E4, and compared them to the electrocardiography (ECG). We collected E4 data simultaneously with ECG in thirty-five older men and women during an overnight sleep recording in the laboratory. We propose a robust approach to resolve the missing inter-beat interval (IBI) data and improve the quality of E4 derived measures. We also evaluated the concordance of heart rate (HR) and heart rate variability (HRV) measures with ECG. The results demonstrate that the automatic E4 heart rate measures capture long-term HRV whilst the short-term metrics are affected by missing IBIs. Our approach provides an effective way to resolve the missing IBI issue of E4 and extracts reliable heart rate measures that are concordant with ECG. Clinical Relevance- This work discusses data quality challenges in heart rate data acquired by wearables and provides an efficient and reliable approach for extracting heart rate measures from the E4 wearable device and validates the metrics in older adults.
More Related Videos
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: