Related Experiment Video
Updated: Aug 29, 2025

Treatment of Platelet Products with Riboflavin and UV Light: Effectiveness Against High Titer Bacterial Contamination
Published on: August 24, 2015
New ultraviolet C light-based method for pathogen inactivation of red blood cell units
Wiebke Handke1, Ute Gravemann2, Thomas H Müller2
1Bavarian Red Cross Blood Service, Nuremberg, Germany.
Background:
Pathogen inactivation (PI) technologies for platelet concentrates and plasma are steadily becoming more established, but new PI treatment options for red blood cells (RBCs), the most commonly used blood component, still need to be developed. We present a novel approach to inactivating pathogens in RBC units employing ultraviolet C (UVC) light.
Methods:
Whole blood-derived leukoreduced RBCs suspended in PAGGS-C, a third generation additive solution, served as test samples, and RBCs in PAGGS-C or SAG-M as controls. Vigorous agitation and hematocrit reduction by diluting the RBCs with additional additive solution during illumination ensured that UVC light penetrated and inactivated the nine bacteria and eight virus species tested. Bacterial and viral infectivity assays and in vitro analyses were performed to evaluate the system's PI capacity and to measure the RBC quality, metabolic, functional, and blood group serological parameters of UVC-treated versus untreated RBCs during 36-day storage.
Results:
UVC treatment of RBCs in the PAGGS-C additive solution did not alter RBC antigen expression, but significantly influenced some in vitro parameters. Compared to controls, hemolysis was higher in UVC-treated RBC units, but was still below 0.8% at 36 days of storage. Extracellular potassium increased early after PI treatment and reached ≤70 mmol/L by the end of storage. UVC-treated RBC units had higher glucose and 2,3-diphosphoglycerate levels than controls.
Conclusion:
As UVC irradiation efficiently reduces the infectivity of relevant bacteria and viruses while maintaining the quality of RBCs, the proposed method offers a new approach for PI of RBC concentrates.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Temperature