Related Experiment Video
Updated: Jul 1, 2026

Investigations on the GaIII Complex of EOB-DTPA and Its 68Ga Radiolabeled Analogue
Published on: August 17, 2016
Determination of hepatic extraction fraction with gadoxetate low-temporal resolution DCE-MRI-based deconvolution
Monchai Phonlakrai1,2, Saadallah Ramadan3,4, John Simpson5,6
1School of Health Sciences, College of Health, Medicine and Wellbeing, The University of Newcastle, Newcastle, New South Wales, Australia.
Introduction:
In this study, we aimed to investigate the feasibility of gadoxetate low-temporal resolution (LTR) DCE-MRI for voxel-based hepatic extraction fraction (HEF) quantification for liver sparing radiotherapy using a deconvolution analysis (DA) method.
Methods:
The accuracy and consistency of the deconvolution implementation in estimating liver function was first assessed using simulation data. Then, the method was applied to DCE-MRI data collected retrospectively from 64 patients (25 normal liver function and 39 cirrhotic patients) to generate HEF maps. The normal liver function patient data were used to measure the variability of liver function quantification. Next, a correlation between HEF and ALBI score (a new model for assessing the severity of liver dysfunction) was assessed using Pearson's correlation. Differences in HEF between Child-Pugh score classifications were assessed for significance using the Kruskal-Wallis test for all patient groups and Mann-Whitney U-test for inter-groups. A statistical significance was considered at a P-value <0.05 in all tests.
Results:
The results showed that the implemented method accurately reproduced simulated liver function; root-mean-square error between estimated and simulated liver response functions was 0.003, and the coefficient-of-variance of HEF was <20%. HEF correlation with ALBI score was r = -0.517, P < 0.0001, and HEF was significantly decreased in the cirrhotic patients compared to normal patients (P < 0.0001). Also, HEF in Child-Pugh B/C was significantly lower than in Child-Pugh A (P = 0.024).
Conclusion:
The study demonstrated the feasibility of gadoxetate LTR-DCE MRI for voxel-based liver function quantification using DA. HEF could distinguish between different grades of liver function impairment and could potentially be used for functional guidance in radiotherapy.